ICD Autonomous Water Control Screen

Product Details
Customization: Available
Material: Metal
Layers: Three
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2025

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Experienced Team
The supplier has 5 foreign trading staff(s) and 3 staff(s) with over 6 years of overseas trading experience
Patents Awarded
The supplier had awarded 2 patents, you can check the Audit Report for more information
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
to see all verified strength labels (33)
  • ICD Autonomous Water Control Screen
  • ICD Autonomous Water Control Screen
  • ICD Autonomous Water Control Screen
  • ICD Autonomous Water Control Screen
  • ICD Autonomous Water Control Screen
  • ICD Autonomous Water Control Screen
Find Similar Products
  • Overview
  • Product Description
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • Exhibition
  • Customer visit
  • FAQ
Overview

Basic Info.

Model NO.
ICD screen
Usage
Liquid Filter, Solid Filter
Type
Filter Elements
Hole Shape
Round
Structure
Combined
Size
2-3/8,2-7/8,3-1/2,4,4-1/2,5,5-1/2,6-5/8,7
Screen ID in
2.441,2.992,3.548,4.000,4.408,4.892,5.921,6.276
Icd Diameter mm
2.5, 3.2
Orifice Holes Holes/Icd
4
Collapse Rating
≥4000psi
Burst Rating
≥1000psi
Transport Package
Cluster Packaging
Specification
customizable
Trademark
Starse
Origin
Shanghai, China
HS Code
7304292000
Production Capacity
150000 Meters/Year

Product Description

Product Description

 

STARSE ICD Water Control Screen

Structure

The ICD (Inflow Control Device) water control screen, integrated with reservoir numerical simulation, enables precise design of orifice quantity, effectively managing the necessary pressure differential for production. This setup prevents premature water and gas breakthrough, delays the coning of edge and bottom water, enhances oil and gas well recovery rates, and extends well longevity.
ICD Autonomous Water Control Screen
ICD Autonomous Water Control Screen
Formation fluids, once filtered through the screen's sleeve, proceed to the ICD water control unit. Here, they undergo flow regulation before being directed into the screen's interior for extraction.
Comprising a support and diversion ring, a rotatable balancing ring, locking and sealing device, the ICD water control device boasts triple-stage flow resistance. Its orifice plates are equipped with tungsten alloy nozzles for superior performance.
  • Set with tungalloy chokes and treated with special hardening process, the ICD nozzles prevent fluid corrosion/erosion and secure the service life
  • Three-stage additional choking capacity can realize the functions of small flowrate but large resistance, greatly expanding application ranges.
  • Convenient field operation, screen inflow rate can be adjusted through rotating equalizing ring for sealing off unnecessary orifices.
  • Reservoir analysis and numerical modeling are used to optimize ICD water control proposal, and realize fluid profile balance, restrain the edge and bottom breakthrough, and extend the well life.
ICD Autonomous Water Control Screen

 

Specification

STARSE ICD Water Control Screen
Pipe Size
in
2-3/8 2-7/8 3-1/2 4 4-1/2 5 5-1/2 6-5/8 7
Pipe weight
lb/ft
4.60 6.40 9.20 9.50 11.60 15.00 17.00 24.00 26.00
Screen ID
in
1.994 2.441 2.992 3.548 4.000 4.408 4.892 5.921 6.276
Filter OD
In
3.215 3.715 4.335 4.841 5.359 5.841 6.343 7.475 7.839
Max. OD
in
3.400 3.900 4.555 5.051 5.559 6.051 6.563 7.685 8.059
ICD Diameter
mm
2.5 2.5 3.2 3.2 3.2 3.2 3.2 3.2 3.2
Orifice Holes
Holes/ICD
4 4 6 6 6 9 9 9 9
Screen Weight
lb/ft
9.69 10.19 14.08 15.18 18.93 22.01 24.69 33.19 35.69
Tensile Strength The screen's tensile strength is over 90% of the base pipe's.
Collapse Rating 4000psi
Burst Rating 1000psi
Remark Base pipe meets API standards, customizable parameters available.
 
Company Profile

 

ICD Autonomous Water Control ScreenICD Autonomous Water Control Screen
Certifications

ICD Autonomous Water Control ScreenICD Autonomous Water Control Screen

Packaging & Shipping

ICD Autonomous Water Control Screen

Exhibition

ICD Autonomous Water Control Screen

Customer visit

ICD Autonomous Water Control Screen

FAQ

Q1. How can I get samples of any product to confirm the quality?
A:1. Please provide us with your exact quantity. We can provide you with samples according to your specifications.
2. We can provide you with counter samples according to the samples you sent.

Q2. How can I get the price of the product?
A:1. Please send us your exact quantity. We can send you samples and pricing details back.
2. If you don't know any specifications. Please send us pictures of your products. We will give you an estimated price according to your pictures based on your needs. But the exact price must be given after we check your original samples.

Q3. I don't know the material or any other material information, how can I order from you.
A: It's the best way if you can send us samples so that we can provide you counter samples to check the quality. We will also quote you a price to verify the cost. After confirming all of these, you can contact our sales to place an order.

Q4. I am a small wholesaler, do you accept small orders?
A: If you are a small wholesaler, no problem, we are willing to grow with you.

Q5. Can you provide OEM or ODM service?
A: Yes. We can accept OEM services. Also, welcome to choose our ODM. Welcome to your inquiry!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier